3.0kw Genuine Balboa Heater Element

Genuine official Balboa replacement 3.0kW Incoloy 800 heating element for use specifically on hot tubs, spas and swim spas with Balboa spa control systems.

 

Balboa Heater Element Overview

  • This official Balboa heater element can be used as a replacement for many Balboa spa heater assemblies such as the 3kw M7 58118, 58107, 58061 and 3kw with pressure switch 50145 along with a huge range of others.
  • The element can be used as a high-quality replacement for other brands of spa heater assemblies with the same 33mm terminal distance.
  • Correct size and shape for use with the M7 heater range keeping the element the correct distance from the M7 sensors.
  • Supplied with new Viton element to heater tube O-rings, 2x 19mm element fixing nuts and 2x 3/8 replacement terminal nuts.
  • 1-year Balboa warranty from the date of purchase.

 

Spa Heater Element Specifications

  • Manufacturer: Balboa Water Group
  • Part Number: 58267
  • Type of Product: Spa or Hot Tub heater element
  • Kilowatt Rating: 3.0kW
  • Volts/Hz: 230/50
  • Amps: 11.5-12.0
  • Element Material: Incoloy 800
  • Length: 250mm
  • Height: 60mm
  • Distance of Terminals: 33mm

 

Element Fitting & Removal Guide

Once you have the heater assembly removed from the spa undo the two 19mm element/tube securing nuts. Push down the two heater terminals and slide out the old element (can be tight but will come out). Slide in the new heater element whilst making sure that you do not bend the terminals too much and ensure the Viton O-rings are seated properly in the recess of each terminal beforehand. Pop up the two terminals through the tube and secure in place with the 2x 19mm nuts.

NOTE: When you have the heater assembly back in the spa control box and you tighten the two heater terminal power wire connections with 3/8 nuts do not allow them to get twisted otherwise the element will be damaged and will not work. Hold the base of the terminal with a 1/4" spanner whilst tightening the 3/8 fixing nuts to prevent this. Element failure from twisted terminals will void any manufacturers warranty. We advise replacing any old pressure switches and heater union gaskets when you fit a new heating element.

 

We Are Here To Help!

It can be a bit confusing choosing your replacement spa heater element as brand names and models are not always written on them. The quickest way is to simply send us some images of the complete spa heater assembly you need the replacement for through our Contact us page and let us do the work for you.

Good to know

Send us a photo

Balboa Approved